Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Int. arch. otorhinolaryngol. (Impr.) ; 23(2): 241-249, 2019. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1015650

RESUMEN

Introduction: The importance of our study lies in the fact that we have demonstrated the occurrence ofmechanical dysfunction within polypoid tissues, which promotes the development of polyps in the nasal cavity. Objective: To change the paradigm of nasal polyposis (NP). In this new conception, the chronic nasal inflammatory process that occurs in response to allergies, to pollution, to changes in the epithelial barrier, or to other factors is merely the trigger of the development of the disease in individuals with a genetic predisposition to an abnormal tissue remodeling process, which leads to a derangement of the mechanical properties of the nasal mucosa and, consequently, allows it to grow unchecked. Data: Synthesis We propose a fundamentally new approach to intervening in the pathological process of NP, addressing biomechanical properties, fluid dynamics, and the concept of surface tension. Conclusion: The incorporation of biomechanical knowledge into our understanding of NP provides a new perspective to help elucidate the physiology and the pathology of nasal polyps, and new avenues for the treatment and cure of NP (AU)


Asunto(s)
Humanos , Pólipos Nasales/fisiopatología , Pólipos Nasales/patología , Inflamación/fisiopatología , Sinusitis/fisiopatología , Fenómenos Biomecánicos , Brasil , Mecánica de Fluidos , Enfermedad Crónica , Edema/fisiopatología , Matriz Extracelular/patología , Presión Hidrostática , Mucosa Nasal/fisiopatología , Mucosa Nasal/patología
3.
Arq. bras. oftalmol ; 80(1): 52-56, Jan.-Feb. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-838776

RESUMEN

ABSTRACT We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an organic dye. Inlay implantation occurred under mechanical microkeratome Lasik flaps set for a depth of 120 µm. The patient returned to the clinic 11 years after surgery and reported loss of near-vision acuity. Clinical examination showed the complete absence of pigments in the device and the total loss of the initial effect on near vision, despite normal distance vision. Manifest refraction remained stable during the follow-up period. Scheimpflug images characterized the loss of the small aperture effect on incoming light. Confocal analysis revealed small hyper-reflective round images on the endothelium and no signs of inflammation.


RESUMO Descrevemos um caso de importante despigmentação de início tardio de implante corneano de pequena abertura implantada para compensação de presbiopia. O paciente foi um dos participantes de ensaio clínico destinado a avaliar a segurança e eficácia do AcuFocusTM ACU-10R160, uma película de poliimida de 10 microns de espessura, tingida com um corante orgânico. A implantação ocorreu sob um flap de Lasik criado por microcerátomo mecânico ajustado para profundidade de 120 µm. O caso aqui descrito foi avaliado 11 anos após a cirurgia, relatando diminuição de acuidade de visão para perto. O exame clínico mostrou ausência total de pigmentos no dispositivo e perda total do efeito inicial na visão de perto, apesar da visão normal para distância. A refração manifesta permaneceu estável durante o período de seguimento. As imagens de Scheimpflug caracterizaram a perda do efeito da abertura pequena na luz entrante. A análise de microscopia confocal revelou pequenas imagens hiper-reflexivas redondas sobre o endotélio, sem sinais de inflamação.


Asunto(s)
Humanos , Femenino , Anciano , Presbiopía/cirugía , Prótesis e Implantes , Sustancia Propia/cirugía , Implantación de Prótesis/instrumentación , Queratomileusis por Láser In Situ/instrumentación , Refracción Ocular , Colgajos Quirúrgicos , Agudeza Visual , Implantación de Prótesis/métodos , Queratomileusis por Láser In Situ/métodos
8.
Arq. bras. oftalmol ; 76(5): 296-300, set.-out. 2013. ilus, tab
Artículo en Inglés | LILACS | ID: lil-690608

RESUMEN

PURPOSE: Identify ideal profiles in patients undergoing to photorefractive laser surgery with the aid of an automated pupillometry and psychometric analysis of patients with visual function questionnaire (VQF 25). METHODS: Seventy-seven patients undergoing photorefractive laser surgery laser (LASIK) were analyzed with the aid of an automated digital pupillometer based on an infrared camera coupled to the optical head of a videokeratography system. Patients underwent complete ophthalmic evaluation and documentation of the pupillary behavior under different intensities of illumination, simulating situations of everyday life. Visual quality function questionnaire, translated to Portuguese was assessed. RESULTS: All patients, regardless of pupillary change under varying conditions of illumination (scotopic, mesopic and photopic) showed improvement in all sub-groups of the VQF 25. Pupil diameter was not the primary determinant of patients' visual satisfaction. CONCLUSION: Despite digital pupillometer has proven to be a useful tool in documenting and understanding of pupil behavior, a set of factors such as psycho-social profile, preoperative ametropy and final residual ametropy, contributed decisively to determine the degree of satisfaction of patients undergoing LASIK.


OBJETIVO: Identificar perfis ideais em pacientes submetidos à cirurgia fotorrefrativa a laser com o auxílio de um pupilômetro automatizado e análise psicométrica de pacientes com o questionário de função visual (VQF 25). MÉTODOS: Setenta e sete pacientes submetidos à cirurgia fotorrefrativa a laser (LASIK) foram analisados com o auxílio de um pupilômetro digital automatizado baseado em uma câmera de infravermelho acoplado à cabeça óptica de um sistema de videoceratografia. Os pacientes foram submetidos à avaliação oftalmológica completa e documentação do comportamento pupilar em diferentes intensidades de iluminação, simulando situações da vida cotidiana. O questionário de qualidade da função visual, traduzido para o Português, foi avaliado. RESULTADOS: Todos os pacientes, independentemente da mudança pupilar em diferentes condições de iluminação (escotópica, mesópica e fotópica) apresentaram melhora em todos os subgrupos do VQF 25. O diâmetro pupilar não foi o principal determinante da satisfação visual dos pacientes. CONCLUSÃO: Apesar do pupilômetro digital ter provado ser uma ferramenta útil na documentação e compreensão do comportamento da pupila, um conjunto de fatores, tais como o perfil psicossocial, ametropia pré-operatória e ametropia residual final, contribuiu de forma decisiva para determinar o grau de satisfação dos pacientes submetidos a LASIK.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Queratomileusis por Láser In Situ/psicología , Reflejo Pupilar/fisiología , Agudeza Visual/fisiología , Queratomileusis por Láser In Situ , Psicometría , Queratectomía Fotorrefractiva/psicología , Queratectomía Fotorrefractiva , Encuestas y Cuestionarios
12.
Arq. bras. oftalmol ; 75(5): 305-305, set.-out. 2012.
Artículo en Portugués | LILACS | ID: lil-667571
16.
Arq. bras. oftalmol ; 74(5): 319-320, set.-out. 2011.
Artículo en Portugués | LILACS | ID: lil-608400
17.
Arq. bras. oftalmol ; 74(5): 348-351, set.-out. 2011. ilus
Artículo en Inglés | LILACS | ID: lil-608407

RESUMEN

PURPOSE: To determine if the corneal epithelium prevents the collagen cross-linking effect. Using immunofluorescence microscopy after CXL, we indirectly analyzed the role of the epithelium as ultraviolet-A (UVA) shield as well as a barrier to riboflavin penetration. METHODS: Fifteen freshly enucleated porcine eyes were divided into 3 groups. The corneal epithelium was kept intact in all groups. Five eyes served as control (Group 1). On group 2, eyes received tetracaine anesthetic drops and topical 0.1 percent riboflavin solution (10 mg riboflavin-5-phosphate in 10 mL 20 percent dextran-T-500). On Group 3, riboflavin was injected into the anterior chamber to allow penetration of the drug through the endothelium. Groups 2 and 3 were exposed to UVA (365 nm, 3 mW/cm²) for 30 minutes. Ultra-thin sections (8 µm) of the corneas were stained with anti-collagen type I and DAPI (4,6-diamidino-2-fenilindole dihydrocloride) and analyzed with fluorescence microscopy. RESULTS: Corneas treated with UVA irradiation and intracameral injection of riboflavin (Group 3) showed greater pattern of collagen organization compared to groups 1 (Control) and 2 (riboflavin and tetracaine eye drops). A yellow stromal staining, which represents the riboflavin diffusion into the stroma, was only observed in eyes injected with riboflavin into the anterior chamber. CONCLUSION: Using immunofluorescence microscopy in porcine corneas, we demonstrated that the corneal epithelium reduces the effectiveness of CXL by preventing the penetration of the drug and not by limiting the UVA transmittance. An inadequate intrastromal concentration of riboflavin may impair CXL effect.


OBJETIVO: Determinar se o epitélio corneano pode impedir ou diminuir o efeito do tratamento com "cross-linking" (CXL). Por meio de microscopia por imunofluorescência, foi indiretamente analisado o efeito do epitélio como escudo aos raios ultravioleta-A (UVA), assim como barreia à penetração da riboflavina. MÉTODOS: Quinze olhos enucleados de porcos foram divididos em 3 grupos. O epitélio corneano foi mantido intacto em todos os grupos. Cinco olhos serviram como controle (Grupo 1). No grupo 2, os olhos foram instilados com colírio anestésico de tetracaína, assim como colírio de riboflavina 0,1 por cento (10 mg de riboflavina-5-fosfato em 10 ml de dextran 20 por cento T-500). No grupo 3, solução de riboflavina foi injetada na câmara anterior para permitir a penetração da droga através do endotélio. Os grupos 2 e 3 foram então expostos à radiação UVA (365 nm, 3 mW/cm²) por 30 minutos. Subsequentemente, cortes ultrafinos (8 µm) das córneas foram marcados com anticolágeno tipo I e DAPI (4,6-diamidino-2-fenilindole dihydrocloride) e analisados com microscópio de imunofluorescência. RESULTADOS: As córneas que receberam injeção intracameral de riboflavina e foram irradiadas com UVA (Grupo 3) mostraram um padrão maior de organização das fibras de colágeno em relação aos grupos 1 (Controle) e 2 (instiladas com colírio anestésico e de riboflavina). Macroscopicamente, a coloração amarelada do estroma, que representa a difusão da riboflavina, foi apenas observada nos olhos que receberam riboflavina intracameral. CONCLUSÃO: Foi demonstrado, através de microscopia por imunofluorescência em córneas de porcos, que o epitélio corneano íntegro diminui a efetividade do CXL por reduzir a penetração da riboflavina, e não por impedir a penetração dos raios UVA. Uma concentração intraestromal inadequada de riboflavina limita o efeito do tratamento.


Asunto(s)
Animales , Epitelio Corneal/efectos de los fármacos , Epitelio Corneal/efectos de la radiación , Fármacos Fotosensibilizantes/farmacocinética , Riboflavina/farmacocinética , Reactivos de Enlaces Cruzados , Colágeno Tipo I/efectos de los fármacos , Colágeno Tipo I/efectos de la radiación , Microscopía Fluorescente , Porcinos , Rayos Ultravioleta
18.
Arq. bras. oftalmol ; 74(2): 91-96, Mar.-Apr. 2011. ilus, graf
Artículo en Portugués | LILACS | ID: lil-593128

RESUMEN

OBJETIVO: Desenvolver um método e um dispositivo para quantificar a visão em candela (cd). Os estudos de medida da visão são importantes para todas as ciências visuais. MÉTODOS: É um estudo teórico e experimental. Foram descritos os detalhes do método psicofísico e da calibração do dispositivo. Foram realizados testes preliminares em voluntários. RESULTADOS: É um teste psicofísico simples e com resultado expresso em unidades do sistema internacional de medidas. Com a descrição técnica será possível reproduzir o experimento em outros centros de pesquisa. CONCLUSÃO: Os resultados aferidos em intensidade luminosa (cd) são uma opção para estudo visual. Esses resultados possibilitarão extrapolar medidas para modelos matemáticos e para simular efeitos individuais com dados aberrométricos.


PURPOSE: To develop a method and a device for vision measurement in candela (cd). Vision measurement studies are important to all visual sciences. METHODS:It is a theoretical and experimental study. The details of psychophysical method and device calibration were described. Preliminary tests were performed on volunteers. RESULTS:It is a simple psychophysical test and results are expressed in International System of Units. With this technical description it will be possible to reproduce the experiment in others research centers. CONCLUSION: The results measured in luminous intensity (cd) are an option for visual studies. These results allow to extrapolate measurements for mathematical models and to simulate data for individual aberrometry effects.


Asunto(s)
Humanos , Sistema Internacional de Unidades/instrumentación , Pruebas de Visión/métodos , Algoritmos , Diseño de Equipo , Modelos Teóricos , Reconocimiento Visual de Modelos , Estimulación Luminosa , Psicofísica , Reproducibilidad de los Resultados , Pruebas de Visión/instrumentación , Agudeza Visual/fisiología , Percepción Visual/fisiología
20.
Arq. bras. oftalmol ; 72(2): 139-145, mar.-abr. 2009. ilus, tab
Artículo en Inglés | LILACS | ID: lil-513906

RESUMEN

PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.


OBJETIVOS: A possibilidade de prever e entender quais propriedades biomecânicas da córnea podem ser responsáveis pelo progresso ou estabilização do ceratocone pode ser uma importante ferramenta clínica e cirúrgica para o oftalmologista. Neste trabalho foi desenvolvido um modelo em elementos finitos da córnea, o qual prevê o surgimento de deformações semelhantes ao ceratocone e sua evolução baseado em propriedades biomecânicas do tecido corneano. MÉTODOS: As propriedades biomecânicas da córnea foram modeladas segundo dados disponíveis na literatura para olhos esquemáticos. Softwares comerciais foram usados para simular propriedades de superfície e material quando a córnea foi submetida a diferentes parâmetros locais de elasticidade. RESULTADOS: As simulações conduzidas aqui mostraram que, dependendo do formato inicial da córnea, mudanças nas propriedades locais do material para diferentes pressões intraoculares, induzem uma protuberância localizada e um aumento significativo de curvatura quando comparado ao restante da córnea. CONCLUSÕES: A técnica apresentada aqui permite o estudo mais preciso e quantitativo da natureza biomecânica do ceratocone. O modelo implementado demonstrou que mudanças locais de propriedades biomecânicas relacionais à elasticidade para uma mesma pressão intraocular, estão intrinsecamente relacionados ao surgimento e evolução de deformações que podem ter relação direta com o ceratocone.


Asunto(s)
Humanos , Córnea/patología , Queratocono/patología , Modelos Biológicos , Fenómenos Biomecánicos , Simulación por Computador , Topografía de la Córnea , Córnea/fisiopatología , Progresión de la Enfermedad , Elasticidad , Análisis de Elementos Finitos , Presión Intraocular , Queratocono/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA